ATC Abstracts

American Transplant Congress abstracts

  • Home
  • Meetings Archive
    • 2022 American Transplant Congress
    • 2021 American Transplant Congress
    • 2020 American Transplant Congress
    • 2019 American Transplant Congress
    • 2018 American Transplant Congress
    • 2017 American Transplant Congress
    • 2016 American Transplant Congress
    • 2015 American Transplant Congress
    • 2013 American Transplant Congress
  • Keyword Index
  • Resources
    • 2021 Resources
    • 2016 Resources
      • 2016 Welcome Letter
      • ATC 2016 Program Planning Committees
      • ASTS Council 2015-2016
      • AST Board of Directors 2015-2016
    • 2015 Resources
      • 2015 Welcome Letter
      • ATC 2015 Program Planning Committees
      • ASTS Council 2014-2015
      • AST Board of Directors 2014-2015
      • 2015 Conference Schedule
  • Search

Functional Capacity Pre-Transplantation Measured by 6 Minute Walk Test and Clinical Outcomes.

T. Alhamad,1 K. Lentine,2 S. Anwar,3 T. Maw,1 T. Horwedel,1 J. Peng,1 K. Saffaf,1 J. Hagopian,1 R. Delos Santos,1 A. Malone,1 D. Brennan.1

1Washington University, St. Louis
2Saint Louis University, St. Louis
3Newcastle Hospital, Newcastle, United Kingdom.

Meeting: 2016 American Transplant Congress

Abstract number: A227

Keywords: Anergy, Echocardiography, Graft failure, Outcome

Session Information

Session Name: Poster Session A: Long Term Outcomes in Kidney Transplantation

Session Type: Poster Session

Date: Saturday, June 11, 2016

Session Time: 5:30pm-7:30pm

 Presentation Time: 5:30pm-7:30pm

Location: Halls C&D

Background:

The 6 minute walk is an inexpensive, low-technology test for measuring a patient's functional capacity and overall fitness. The utility of 6 minute walk test (6MWT) in kidney transplant evaluation and its associations with post-transplant clinical outcomes have not been described.

Methods:

We performed a retrospective study of kidney transplant recipients at one large center (2000 to 2014) who underwent 6MWT before transplantation. A questionnaire administered during the evaluation asked candidates “How far can you walk without difficulty?” Patients with answers indicating limited ability were further evaluated by the 6MWT. Associations between walking distance and post-transplant graft failure and patient death were examined by Cox regression including adjustment for recipient, donor and transplant factors.

Results:

During the study period, 489 recipients underwent 6MWT and were categorized according to quartile of walking distance as: short walk (n=123) (<1101 feet), medium walk (n=246, middle quartiles) (1101-1414 feet), and long walk (n=121) (>1414 feet).

Compared to long walk distance, short 6MWT distance was not associated with increased risk for graft failure or patient death at 1, 3, and 5 years post-transplant after covariate adjustment. However, at 10 years, short 6MWT distance was independently associated with increased risk of graft failure (aHR 4.2, CI 1.84–9.57). To a lesser degree, medium 6MWT distance was also associated with higher risk of graft failure (aHR 2.22, CI 1.03–4.8) compared to the short walk distance. No significant differences were noted in risks of post-transplant mortality according to 6MWT level.

Conclusion:

Results of a 6MWT correlated with long-term but not short-term graft outcomes after kidney transplantation. This observation may reflect selection bias for other favorable characteristics predicting excellent 5 year outcomes among candidates with short walk capacity chosen for transplantation. Further work should examine the implications of 6MWT for access to transplantation and waitlist survival.

CITATION INFORMATION: Alhamad T, Lentine K, Anwar S, Maw T, Horwedel T, Peng J, Saffaf K, Hagopian J, Delos Santos R, Malone A, Brennan D. Functional Capacity Pre-Transplantation Measured by 6 Minute Walk Test and Clinical Outcomes. Am J Transplant. 2016;16 (suppl 3).

  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
  • Click to print (Opens in new window) Print

To cite this abstract in AMA style:

Alhamad T, Lentine K, Anwar S, Maw T, Horwedel T, Peng J, Saffaf K, Hagopian J, Santos RDelos, Malone A, Brennan D. Functional Capacity Pre-Transplantation Measured by 6 Minute Walk Test and Clinical Outcomes. [abstract]. Am J Transplant. 2016; 16 (suppl 3). https://atcmeetingabstracts.com/abstract/functional-capacity-pre-transplantation-measured-by-6-minute-walk-test-and-clinical-outcomes/. Accessed June 1, 2025.

« Back to 2016 American Transplant Congress

Visit Our Partner Sites

American Transplant Congress (ATC)

Visit the official site for the American Transplant Congress »

American Journal of Transplantation

The official publication for the American Society of Transplantation (AST) and the American Society of Transplant Surgeons (ASTS) »

American Society of Transplantation (AST)

An organization of more than 3000 professionals dedicated to advancing the field of transplantation. »

American Society of Transplant Surgeons (ASTS)

The society represents approximately 1,800 professionals dedicated to excellence in transplantation surgery. »

Copyright © 2013-2025 by American Society of Transplantation and the American Society of Transplant Surgeons. All rights reserved.

Privacy Policy | Terms of Use | Cookie Preferences