ATC Abstracts

American Transplant Congress abstracts

  • Home
  • Meetings Archive
    • 2022 American Transplant Congress
    • 2021 American Transplant Congress
    • 2020 American Transplant Congress
    • 2019 American Transplant Congress
    • 2018 American Transplant Congress
    • 2017 American Transplant Congress
    • 2016 American Transplant Congress
    • 2015 American Transplant Congress
    • 2013 American Transplant Congress
  • Keyword Index
  • Resources
    • 2021 Resources
    • 2016 Resources
      • 2016 Welcome Letter
      • ATC 2016 Program Planning Committees
      • ASTS Council 2015-2016
      • AST Board of Directors 2015-2016
    • 2015 Resources
      • 2015 Welcome Letter
      • ATC 2015 Program Planning Committees
      • ASTS Council 2014-2015
      • AST Board of Directors 2014-2015
      • 2015 Conference Schedule
  • Search

In Situ Aortic Flush with Lactated Ringer's (LR) Solution During Donation After Brain Death (DBD) Organ Procurement Provides Similar Outcomes and Significantly Decreases Costs in Kidney and Liver Transplantation Compared to Standard Preservation Solutions.

S. Rudich, P. Lange.

Medical Division, Gift of Life Michigan, Ann Arbor, MI.

Meeting: 2016 American Transplant Congress

Abstract number: D122

Keywords: Cadaveric organs, Graft function, Perfusion solutions, Procurement

Session Information

Session Name: Poster Session D: Ischemia Reperfusion Injury: Clinical Update

Session Type: Poster Session

Date: Tuesday, June 14, 2016

Session Time: 6:00pm-7:00pm

 Presentation Time: 6:00pm-7:00pm

Location: Halls C&D

PURPOSE: To determine if LR, when used as the initial in situ aortic flush during DBD renal and hepatic procurement, was safe, effective, and non-inferior to either UW or HTK.

METHODS: UNOS data were queried as to 3 different in situ aortic flush solutions used during DBD organ procurement: LR, UW, and HTK; repeat and multi-organ txps were excluded. Data were analyzed from July 2004 to April 2012.

RESULTS: During this period, UNOS recorded 597 OLTs using LR as in situ flush, vs 26331 and 9546 using UW and HTK, respectively. All groups were similar in regard to most demographic variables. Cold ischemic time (CIT) was 8.0, 7.1 and 6.9 hrs for donors in the LR, UW, and HTK flush groups, respectively. There were no statistical differences in either 1 and 3 yr allograft or patient survival. Allograft failure within 7 days post-OLT was similar: 2.7%, vs 2.4 and 2.9% for LR, UW, and HTK groups. Allograft failure within 1 yr OLT due to biliary complications was less for the LR group (0.3%), vs the UW and HTK groups (0.7 and 0.6%). The need to re-list a recipient for any reason within 6 mos, 1 yr, or ever, was the same for each group.

In terms of renal txp data, 644 renal txps were performed using LR as the aortic in situ flush, vs 43375 and 15325 using UW and HTK, respectively. Terminal Cr was similar, but CIT was shorter in the LR group (13.6 hrs, vs 17.9 and 18.0 hrs, for LR, vs UW and HTK, respectively). 80% of LR kidneys were pumped, vs 31.0 and 33.1% for the UW and HTK groups, respectively. However, DGF rate for the LR group was 9.9%, vs 23.0 and 20.2 % for the UW and HTK groups, respectively. Adjusted regression modeling showed that the use of LR was significantly associated with lower odds of DGF (AOR=0.48, p<.0001). One and 3 yr allograft and patient survival were not statistically different between the donor flush groups.

During a single DBD procurement, from 6 to 8 L of UW or HTK will be used as the in situ aortic flush. If one compares this cost to that of LR, a savings of over $1500 can be realized.

CONCLUSIONS: Using LR as in situ aortic flush for DBD procurement leads to hepatic and renal transplant outcomes which were as good as standard (UW/HTK) flush. Cost savings for the OPO can be profound, with other, perhaps more important potential savings for txp centers and recipients, insofar as less DGF and biliary tract complications.

CITATION INFORMATION: Rudich S, Lange P. In Situ Aortic Flush with Lactated Ringer's (LR) Solution During Donation After Brain Death (DBD) Organ Procurement Provides Similar Outcomes and Significantly Decreases Costs in Kidney and Liver Transplantation Compared to Standard Preservation Solutions. Am J Transplant. 2016;16 (suppl 3).

  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
  • Click to print (Opens in new window) Print

To cite this abstract in AMA style:

Rudich S, Lange P. In Situ Aortic Flush with Lactated Ringer's (LR) Solution During Donation After Brain Death (DBD) Organ Procurement Provides Similar Outcomes and Significantly Decreases Costs in Kidney and Liver Transplantation Compared to Standard Preservation Solutions. [abstract]. Am J Transplant. 2016; 16 (suppl 3). https://atcmeetingabstracts.com/abstract/in-situ-aortic-flush-with-lactated-ringers-lr-solution-during-donation-after-brain-death-dbd-organ-procurement-provides-similar-outcomes-and-significantly-decreases-costs-in-kidney-and-liver/. Accessed May 21, 2025.

« Back to 2016 American Transplant Congress

Visit Our Partner Sites

American Transplant Congress (ATC)

Visit the official site for the American Transplant Congress »

American Journal of Transplantation

The official publication for the American Society of Transplantation (AST) and the American Society of Transplant Surgeons (ASTS) »

American Society of Transplantation (AST)

An organization of more than 3000 professionals dedicated to advancing the field of transplantation. »

American Society of Transplant Surgeons (ASTS)

The society represents approximately 1,800 professionals dedicated to excellence in transplantation surgery. »

Copyright © 2013-2025 by American Society of Transplantation and the American Society of Transplant Surgeons. All rights reserved.

Privacy Policy | Terms of Use | Cookie Preferences